We have a final design

With two revisions from WUFI and some Therm modeling, we have a    final design.  We will be submitting to PHIUS for pre certification soon and expect very little revisions needed from that review.  Once we get pre-certified, we will then be able to submit plans to the County for permitting.

  1. CLT construction
  2. RockWool insulation.  10″ walls, 21″ roof, 6″ under slab
  3. Prosoco Cat5, Fast Flash and Joint and Seam liquid WRB and AB
  4. 11kw solar array
  5. Rammed earth knee wall under solar array
  6. Minotair ERV
  7. Earth tube
  8. Triple pane windows
  9. Triple pane entry door and two custom Passive doors
  10. Rain screen cladding system
  11. Incorporate some Biophilic designs
  12. Capture 100% rainwater runoff for domestic use

= PHIUS + and Source Zero certified

= Zero Energy building

 

CFSD.Model

Screen Shot 2018-02-13 at 5.24.30 PMScreen Shot 2018-03-09 at 7.51.59 AM